J Orthod Sci ; 12: 50, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37881657

RESUMEN

A variety of metals and alloys are employed in the field of orthodontics, primary of which happen to be the construction of wires. Through this systematic review, we aimed to assess the various metallurgical characteristics of the said metals and alloys. Four hundred and eighty-two documents in total were found after a thorough search of the online journals, and 169 of the papers were initially chosen. Ultimately, 16 documents were selected that satisfied the necessary inclusion and exclusion criteria, primarily in vitro studies, literature reviews, and comparative analyses. NiTi alloy was found to be the most commonly used alloy in construction of orthodontic wires across all the studies that we had selected for our review. It also had better performance and consistency in terms of its usage as depicted by the meta-analysis performed, with stainless steel wires being a close second primarily due to its lesser cost compared to the former. Metallurgy and orthodontics are inextricably linked with one another. The various components of orthodontics such as wires, pliers, and other instruments utilize the metallurgical characteristics of metals and alloys that are specially prepared for the challenges of this field. PROSPERO Registration Number: CRD42022378444.

2.
J Orthod Sci ; 12: 51, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37881658

RESUMEN

Infection control is essential to protect both the doctor and the patient by preventing the spread of infectious diseases. There is no exception in the field of dentistry, particularly in orthodontics, where numerous appliances are used for a variety of functions and also because the mouth cavity has the highest concentration of bacteria of any body part. Through this systematic review, we aimed to assess the various methods of sterilization employed in an orthodontic setting. Using relevant keywords, reference searches, and citation searches, the databases such as PubMed, MEDLINE, Web of Science, Cochrane, and Scopus were all searched; a total of 206 documents were found, of which 113 were initially selected. The remaining 23 distinct papers were initially made available after 90 publications that were identical to or similar to one another were eliminated. The final selection was made from eight documents that met all inclusion and exclusion requirements. The existing methods of sterilization were found to be competent in dealing with the microorganisms found in a typical orthodontic setting. The chemical method of sterilization was the norm in most of the studies that we assessed, with glutaraldehyde and peracetic acid (PAA) being the most commonly employed compounds for disinfection. PROSPERO Registration Number: CRD42022380831.

3.
J Int Soc Prev Community Dent ; 13(4): 265-272, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37876586

RESUMEN

Aims and Objectives: To perform a bibliometric study to identify and evaluate articles associated with "orthodontic wires" indexed in six databases (PubMed, Embase, Cochrane, Scopus, Lilacs, and Google Scholar) from 2010 to 2022. Materials and Methods: The search strategy in PubMed combined different medical subject heading terms with free-text words and was adjusted for each selected database. The retrieved documents were original English articles containing the keywords used in the search strategies related to orthodontic wires. Collected data consisted of journal name, nationality, field, JIF-2 and JIF-5, SJR, CiteScore, Q and H-index, and categorization of the study. Results: In total, 417 articles were retrieved from the initial search. After the exclusion criteria, 257 articles remained. The most common theme was mechanical properties, with basic studies as the main categorization. Conclusions: This bibliometric survey provides an overview of orthodontic wires publications that might help orthodontists to understand the tendency of the studies on this subject. The retrieved papers were published in 100 journals, including 15 orthodontic journals, mainly in the first and second quartiles. Europe and America were the continents with the highest number of papers. The United States was the country with the highest number of journals on the topic. AJODO presented the highest h-index among the retrieved orthodontic journals. Brazil represented the principal institutions of origin of the listed articles. There was a tendency to increase the number of publications on orthodontic wires over the years. These findings indicate that research on orthodontic wires is still contemporary and relevant.

4.
J Contemp Dent Pract ; 24(4): 228-237, 2023 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-37469261

RESUMEN

AIM: To evaluate the effects of two preprocedural mouthrinses, hydrogen peroxide (H2O2) and povidone iodine (PI) on the surface characteristics and mechanical properties of nickel-titanium (NiTi) and stainless steel (SS) orthodontic archwires. MATERIALS AND METHODS: Five wire specimens were used, each (0.016" NiTi, 0.016" SS wires, 0.016 × 0.022" NiTi and 0.016 × 0.022" SS wires) specimen was cut into 30 mm lengths and immersed in 9% of artificial saliva and 91% of two preprocedural mouthrinse solutions: 1.5% hydrogen peroxide mouthwash, 0.2% povidone-iodine mouthwash, and distilled water (control group) for 90 minutes and incubated at 37°C. The wire specimens were then subjected to a three-point bending test for mechanical testing and viewed under a scanning electron microscope (SEM) to evaluate their surface characteristics. The collected data were analyzed using one-way analysis of variance (ANOVA) and Bonferroni post hoc test. RESULTS: The results showed a significant increase in the flexural modulus (E) of Nitinol wires in povidone-iodine gargle (p < 0.05) and a significant increase in the E of stainless steel wires in hydrogen peroxide mouthwash (p < 0.05). Analysis using SEM showed varying qualitative surface changes in the form of corrosion, voids, and ridges on the wires after exposure to both the mouthwashes. CONCLUSION: Though there were significant changes in the flexural modulus of archwires for both the mouthwashes, hydrogen peroxide did not show a significant difference in the E of wires at most of the deflection intervals when compared with the other two solutions, hence, could be used in orthodontic patients as an effective preprocedural mouthrinse. CLINICAL SIGNIFICANCE: Preprocedural mouthrinses can cause surface irregularities on the wires which in turn lead to an increase in friction at the bracket-wire interface, thereby disrupting effective tooth movement and extending the orthodontic treatment time.


Asunto(s)
Peróxido de Hidrógeno , Antisépticos Bucales , Humanos , Antisépticos Bucales/farmacología , Povidona Yodada/farmacología , Alambres para Ortodoncia , Acero Inoxidable , Aleaciones Dentales , Titanio , Ensayo de Materiales , Propiedades de Superficie
5.
Front Dent ; 20: 13, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37312830

RESUMEN

Objectives: This study aimed to assess the effect of different forms of fluoride application on surface roughness of rhodium-coated nickel-titanium (NiTi) orthodontic wires. Materials and Methods: This randomized clinical trial was conducted on 15 patients randomly divided into three groups: toothbrush with Oral-B toothpaste only, Oral-B toothpaste, and daily mouthwash, Oral-B toothpaste, and sodium fluoride gel. The surface roughness indices of orthodontic wires including arithmetic mean height (Sa), root mean square height, root mean square gradient, developed interfacial area ratio (Sdr) and maximum surface height were measured by atomic force microscopy at baseline and after 6 weeks of application in the patients' mouths. Data were analyzed by paired t-test, ANOVA, Games-Howell, and Tukey-HSD tests (P<0.05). Results: All surface roughness parameters in all three groups showed a significant increase after intervention, except for Sa in the toothpaste-only group (P=0.057) and Sdr in the sodium fluoride gel group (P=0.064). Conclusion: The surface roughness of rhodium-coated NiTi orthodontic wires increases following the use of different forms of fluoride.

6.
J Orthod Sci ; 12: 3, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37351401

RESUMEN

OBJECTIVE: To evaluate in-vitro surface characteristics and frictional properties of orthodontic stainless steel and beta-titanium archwires after surface modification with different concentrations and coating time of titanium oxide (TiO2) nanoparticles by Sol-gel dip coating method. MATERIALS AND METHODS: The experiment was carried out with 4 different concentrations (1:2, 1:4, 1:6, and 1:8) and three different dipping durations (24 hours, 48 hours, and 72 hours) over ten main test groups of SS and TMA archwires with uncoated wires acting as control in both dry and wet conditions. Phase analysis and surface characterization of TiO2 was analyzed by X-ray Diffractometry, surface evaluation with the help of scanning electron microscopy (SEM), and frictional characteristics were evaluated. RESULTS: Among all the concentrations 1:6 ratio with 48 hours of dipping duration showed better surface characteristics. A statistically significant difference in frictional coefficient was observed in both SS and TMA wires than their respective controls (p = 0.001). Intragroup comparison among SS and TMA groups showed that groups with 1:6 ratio and 48 hours dipping duration had least frictional coefficient in both dry and wet conditions (p = 0.001). Intergroup comparison between SS and TMA showed that SS group had significantly reduced friction than TMA (p = 0.001) except in few groups. CONCLUSION: TiO2 nanoparticle with a concentration ratio of 1:6 and 48 hours dipping duration is recommended for surface modification of orthodontic archwires.

7.
J Orthod Sci ; 12: 9, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37351408

RESUMEN

OBJECTIVE: The aim of this 2-arm parallel study was to evaluate the alignment efficiency of heat-activated nickel-titanium (NiTi-TE) and superelastic nickel titanium (NiTi-PSE) archwires over the first 3 months of orthodontic treatment and compare these groups. SETTING AND SAMPLE POPULATION: Randomized, double-blind, controlled, single-center trial in 52 patients with fixed orthodontic appliances from an orthodontic graduate program in the permanent dentition and moderate crowding in the lower arch. MATERIAL AND METHODS: Patients were randomly allocated to one of two interventions: NiTi-TE and NiTi-PSE archwires, 0.014-inch (3M Unitek™, CA, USA) with a follow-up period of 3 months. The primary outcome was the alignment efficiency determined by the reduction in Little's irregularity index (mm), measured in three points, T0: before the start of orthodontic treatment, T1: 1 month later, T2: 2 months later, T3: 3 months later. Data were analyzed using independent sample t tests and repeated measures ANOVA. RESULTS: 52 patients (NiTi-TE n = 26; NiTi-PSE n = 26) were randomized and analyzed (average age: 21.73; standard deviation (SD): 6.07; average lower anterior irregularity: 5.20; SD: 0.76) for intention-to-treat (ITT) analysis. No statistically significant differences between the groups were found (mean of the differences: T1: 0.20; 95% CI: -0.558; 0.958; T2: 0.49: 95% CI: -0.339; 1.319; T3: 0.33; 95% CI: -0.308; 0.968). The resolution of crowding with each of the wires was significant (P < 0.0001) at all times. Twelve participants (2 treated with NiTi-TE and 10 treated with NiTi-PSE) lost follow-up due to face-to-face dental-procedures restrictions during the COVID-19 pandemic, the missing data was imputed. CONCLUSIONS: NiTi-TE and NiTi-PSE wires of 0.014-inch were similar in their clinical efficiency for the resolution of crowding during the first 3 months of orthodontic treatment. REGISTRATION: Clinical Trials NCT03256279.

8.
Materials (Basel) ; 16(10)2023 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-37241310

RESUMEN

The shape of superelastic Nickel-Titanium (NiTi) archwires can be adjusted with thermal treatments using devices such as the Memory-MakerTM (Forestadent), which potentially affects their mechanical properties. The effect of such treatments on these mechanical properties was simulated by means of a laboratory furnace. Fourteen commercially available NiTi wires (0.018″ × 0.025″) were selected from the manufacturers American Orthodontics, Dentaurum, Forestadent, GAC, Ormco, Rocky Mountain Orthodontics and 3M Unitek. Specimens were heat treated using different combinations of annealing duration (1/5/10 min) and annealing temperature (250-800 °C) and investigated using angle measurements and three-point bending tests. Complete shape adaptation was found at distinct annealing durations/temperatures for each wire ranging between ~650-750 °C (1 min), ~550-700 °C (5 min) and ~450-650 °C (10 min), followed by a loss of superelastic properties shortly afterwards at ~750 °C (1 min), ~600-650 °C (5 min) and ~550-600 °C (10 min). Wire-specific working ranges (complete shaping without loss of superelasticity) were defined and a numerical score (e.g., stable forces) was developed for the three-point bending test. Overall, the wires Titanol Superelastic (Forestadent), Tensic (Dentaurum), FLI CuNiTi27 (Rocky Mountain Orthodontics) and Nitinol Classic (3M Unitek) proved to be the most user-friendly. Thermal shape adjustment requires wire-specific working ranges to allow complete shape acceptance and high scores in bending test performance to ensure permanence of the superelastic behaviour.

9.
Int J Mol Sci ; 24(8)2023 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-37108082

RESUMEN

Surface coating technology is an important way to improve the properties of orthodontic appliances, allowing for reduced friction, antibacterial properties, and enhanced corrosion resistance. It improves treatment efficiency, reduces side effects, and increases the safety and durability of orthodontic appliances. Existing functional coatings are prepared with suitable additional layers on the surface of the substrate to achieve the abovementioned modifications, and commonly used materials mainly include metal and metallic compound materials, carbon-based materials, polymers, and bioactive materials. In addition to single-use materials, metal-metal or metal-nonmetal materials can be combined. Methods of coating preparation include, but are not limited to, physical vapor deposition (PVD), chemical deposition, sol-gel dip coating, etc., with a variety of different conditions for preparing the coatings. In the reviewed studies, a wide variety of surface coatings were found to be effective. However, the present coating materials have not yet achieved a perfect combination of these three functions, and their safety and durability need further verification. This paper reviews and summarizes the effectiveness, advantages and disadvantages, and clinical perspectives of different coating materials for orthodontic appliances in terms of friction reduction, antibacterial properties, and enhanced corrosion resistance, and discusses more possibilities for follow-up studies as well as for clinical applications in detail.


Asunto(s)
Alambres para Ortodoncia , Titanio , Fricción , Corrosión , Titanio/química , Ensayo de Materiales , Propiedades de Superficie , Materiales Biocompatibles Revestidos/química , Aparatos Ortodóncicos , Antibacterianos/farmacología
10.
Braz. dent. j ; 34(2): 129-135, Mar.-Apr. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1439573

RESUMEN

Abstract This study aimed to assess and correlate initial surface roughness and frictional resistance of rectangular CuNiTi wires inserted in different self-ligating brackets. The sample consisted of 40 bracket-wire sets (rectangular CuNiTi wires of 0.017" x 0.025" and passive self-ligating brackets) divided into four groups (n=10): metallic self-ligating bracket and metallic CuNiTi wire (G1); metallic self-ligating bracket and rhodium-coated CuNiTi wire (G2); esthetic self-ligating bracket and metallic wire (G3); esthetic self-ligating bracket and rhodium-coated CuNiTi wire (G4). The initial surface roughness of the wires was examined with a Surfcorder roughness meter, model SE1700. Later, frictional resistance was assessed in an Instron 4411 universal testing machine at a speed of 5 mm/min, in an aqueous medium at 35°C. Microscopic analyses of surface morphology were performed with scanning electron microscopy, using an LEO 1430, with magnifications of 1000X. Generalized linear models were applied, considering the 2 x 2 factorial (bracket type x wire type), at a 5% significance level. Regardless of bracket type, the groups with esthetic wires presented higher initial surface roughness than the groups with metallic wires (p<0.05). There was no significant difference between the different bracket-wire sets for frictional resistance and no significant correlation between frictional resistance and initial surface roughness in the environment studied. It is concluded that esthetic wires presented higher initial surface roughness but did not interfere with the frictional resistance between brackets and wires.


Resumo O objetivo deste estudo foi avaliar e correlacionar a rugosidade superficial inicial e a resistência a fricção dos fios CuNiTi retangulares inseridos em diferentes bráquetes autoligados. A amostra foi composta por 40 conjuntos bráquetes-fios (fios retangulares CuNiTi de 0.017" x 0.025" e braquetes autoligados passivos), divididos em 4 grupos (n=10): bráquete autoligado metálico e fio CuNiti metálico (G1); braquete autoligado metálico e fio CuNiti com revestimento de rhodium (G2); bráquete autoligado estético e fio metálico (G3); bráquete autoligado estético e fio CuNiti com revestimento de rhodium (G4). A rugosidade superficial inicial do fio foi examinada com um rugosímetro Surfcorder modelo SE1700. Posteriormente, a resistência a fricção foi avaliada em uma máquina de ensaios universal Instron 4411, a uma velocidade de 5mm/min em meio aquoso à 35oC. Análises microscópicas da morfologia de superfície foram realizadas por microscopia eletrônica de varredura, utilizando um LEO 1430, com ampliações de 1000X. Foram aplicados modelos lineares generalizados, considerando o fatorial 2 x 2 (tipo de bráquete x tipo de fio), com o nível de significância de 5%. Independentemente do tipo de bráquete, os grupos com fios estéticos apresentaram maior rugosidade superficial inicial que os grupos com fios metálicos (p<0,05). Não houve diferença significativa entre os diferentes conjuntos bráquetes-fios quanto a resistência à fricção e não houve correlação significativa entre a resistência a fricção e a rugosidade superficial inicial no ambiente estudado. Conclui-se que os fios estéticos apresentaram maior rugosidade superficial inicial porém não interferiram na resistência a fricção entre os braquetes e os fios.

11.
Int Orthod ; 21(1): 100720, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36565514

RESUMEN

AIM: The mechanical and surface characteristics of Copper NiTi wires following intraoral aging in an important topic. This ex-vivo study is designed to assess the three most important mechanical properties; torsional stiffness, 3-point bending and surface hardness of the as-received Copper NiTi orthodontic archwires and compare them to the retrieved ones. MATERIAL AND METHODS: In this study, 50 round CuNiTi (0.016 inch) and 50 rectangular (0.018×0.025 inch) CuNiTi orthodontic wires (American Orthodontics, Tanzo Copper Nickel Titanium, Sheboygan, WI) were tested. The groups were as follow: 25 as-received 0.016 inch round CuNiTi archwires (group 1), 25 as-retrieved 0.016 inch round CuNiTi archwires (group 2), 25 as-received 0.018×0.025 inch rectangular CuNiTi archwires (group 3), and 25 as-retrieved 0.018×0.025 inch rectangular CuNiTi archwires (group 4). The physical properties of all of the samples were examined using Vickers hardness, bending and torsional tests. The Kolmogorov-Smirnov test was applied to assess the normal distribution of data. An independent t-test was used to compare the variables between the groups. RESULTS: The results showed that the hardness does not significantly differ between the as-received and as-retrieved archwires in both 0.016 and 0.018×0.025 inch archwires (P< 0.05). The bending test of the round wires showed that the values of the activation forces in the as-received ones were significantly higher than those of the as-retrieved (P=0.00). The torsional and bending test results of rectangular wires showed that the amounts of forces exerted from the as-retrieved archwires were significantly higher than the new archwires (P=0.00). CONCLUSIONS: Round CuNiTi archwires could be retied in the succeeding visits. However, the bending activation that declines significantly should be took into consideration. On the other hand, since bending and torsion activation of CuNiTi rectangular archwires increased after intraoral use, these wires should be retied cautiously.


Asunto(s)
Aleaciones Dentales , Níquel , Humanos , Titanio , Cobre , Ensayo de Materiales , Alambres para Ortodoncia , Propiedades de Superficie
12.
Dental press j. orthod. (Impr.) ; 28(1): e2319380, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1430276

RESUMEN

ABSTRACT Introduction: Fixed orthodontic retainers are very important for treatment stability; however, adverse effects on the health of periodontium can be caused as a result of deposition of plaque and calculus. Objectives: To compare and determine the effects of two mandibular fixed lingual retainers on the periodontal status, and to test the null hypothesis that there would be no significant difference on the periodontium health between the patients using fiber-reinforced composite (FRC) or multistranded wire (MSW) fixed retainers. Methods: A total of 60 subjects were recruited, out of which 6 were excluded and 2 dropped out during the study. Hence, 52 subjects with mean age of 21.5 ± 3.6 years were included in the study. The sample was composed by 8 males (15.4%) and 44 females (84.6%). The participants were randomly divided into two groups: Group 1 received fiber-reinforced composite retainer, while Group 2 received multistranded wire retainer. After insertion, plaque index, calculus index, gingival index and bleeding on probing were compared, after three months (T1), six months (T2), nine months (T3) and twelve months (T4), using Mann-Whitney test with p-value ≤ 0.05 as significant. Results: It could be seen that the health of periodontium deteriorated with the passage of time from T1 to T4 in both group of retainers. However, no statistically significant differences were found between the two groups (p> 0.05). Conclusion: The results of the study indicate that there was no significant difference on the health of periodontium between the patients with FRC and MSW fixed retainers, hence, the null hypothesis was accepted.


RESUMO Introdução: As contenções ortodônticas fixas são muito importantes para a estabilidade do tratamento; no entanto, elas podem causar efeitos adversos na saúde do periodonto, como resultado da deposição de placa e cálculo. Objetivos: Comparar e determinar os efeitos na saúde periodontal de duas contenções inferiores coladas por lingual, e testar a hipótese nula de que não haveria diferença significativa na saúde periodontal entre os pacientes usando contenções fixas de compósito reforçado com fibra (FRC) ou de fio multitrançado (MSW). Métodos: No total, 60 indivíduos foram recrutados, dos quais 6 foram excluídos e 2 desistiram durante o estudo. Assim, foram incluídos no estudo 52 indivíduos com média de idade de 21,5 ± 3,6 anos. A amostra foi composta por 8 homens (15,4%) e 44 mulheres (84,6%). Os participantes foram divididos aleatoriamente em dois grupos: O Grupo 1 recebeu contenção de compósito reforçado com fibra, enquanto o Grupo 2 recebeu contenção de fio multitrançado. Após três meses (T1), seis meses (T2), nove meses (T3) e doze meses (T4) da colagem, foram comparados os índices de placa e de cálculo, índice gengival e sangramento à sondagem, usando o teste de Mann-Whitney com p ≤ 0,05 como significativo. Resultados: Pôde-se observar que a saúde periodontal piorou com o passar do tempo, de T1 a T4, em ambos os grupos de contenções. No entanto, não foram encontradas diferenças estatisticamente significativas entre os dois grupos (p> 0,05). Conclusão: Os resultados do estudo indicam que não houve diferença significativa na saúde periodontal entre os pacientes com contenções fixas FRC e MSW; portanto, a hipótese nula foi aceita.

13.
Dental press j. orthod. (Impr.) ; 28(6): e2323177, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1528517

RESUMEN

ABSTRACT Objective: To compare alignment efficiency and root resorption between nickel-titanium (NiTi) and copper-nickel-titanium (CuNiTi) archwires after complete alignment in mandibular anterior region. Methods: In this two-arm parallel single-blind randomized controlled trial, forty-four patients with Class I malocclusion with mandibular anterior crowding were recruited form orthodontic clinic of All India Institute of Medical Sciences (Jodhpur, India). Patients were randomly allocated into NiTi and CuNiTi groups, with a 1:1 allocation. Alignment was performed using 0.014-in, 0.016-in, 0.018-in, 0.019x0.025-in archwire sequence in the respective groups, which terminated in 0.019 x 0.025-in stainless-steel working archwire. The primary outcome was alignment efficiency, measured on study models from baseline (T0) to the first, second, third, fourth and fifth-month (T5). Secondary outcome was root resorption, measured from CBCT scans taken at T0 and T5. Mixed-factorial ANOVA was used to compare Little's Irregularity Index (LII). For assessing the proportion of patients with complete alignment at the end of each month, Kaplan-Meier survival curve was built and time to treatment completion was compared between groups using log rank test. Paired t-test was used to assess external apical root resorption (EARR) within groups, whereas independent t-test was used to evaluate LII and EARR between the groups. Results: Twenty-two patients were recruited in each group. One patient was lost to follow-up in the CuNiTi group. No statistically significant differences were observed in alignment efficiency between the groups (p>0.05). Intergroup comparison revealed that the changes in root measurement in three-dimensions were not statistically significant (p>0.05), except for mandibular right central incisor, which showed increased resorption at root apex in NiTi group (p<0.01). Conclusion: The two alignment archwires showed similar rate of alignment at all time points. Root resorption measurement did not differ between the NiTi and CuNiTi groups, except for the mandibular right central incisor, which showed more resorption in NiTi group.


RESUMO Objetivo: Comparar os fios de níquel-titânio (NiTi) e de cobre-níquel-titânio (CuNiTi) quanto à eficiência do alinhamento e quantidade de reabsorção radicular, após alinhamento completo dos dentes da região anterior inferior. Métodos: Neste estudo clínico randomizado, cego, paralelo, de dois braços, quarenta e quatro pacientes com má oclusão Classe I e apinhamento anterior inferior foram recrutados na clínica ortodôntica do All India Institute of Medical Sciences (Jodhpur, India). Os pacientes foram alocados aleatoriamente nos grupos NiTi e CuNiTi, na proporção de 1:1. O alinhamento foi realizado usando a sequência de fios 0,014", 0,016", 0,018" e 0,019" x 0,025" nos respectivos grupos, finalizando com o arco de trabalho 0,019" x 0,025" de aço inoxidável. O desfecho primário foi a eficiência do alinhamento, medida nos modelos de estudo nos tempos inicial (T0) e após um, dois, três, quatro e cinco meses (T5). O desfecho secundário foi a reabsorção radicular, medida a partir de tomografias computadorizadas realizadas em T0 e T5. ANOVA fatorial mista foi utilizada para comparar o Índice de Irregularidade de Little (IIL). Para avaliar a proporção de pacientes com alinhamento completo ao fim de cada mês, foi construída uma curva de sobrevida pelo método de Kaplan-Meier, e o tempo até o fim do tratamento foi comparado entre os grupos por meio do teste log-rank. Um teste t pareado foi utilizado para avaliar a reabsorção radicular apical externa (RRAE) dentro dos grupos, enquanto um teste t independente foi utilizado para avaliar o IIL e a RRAE entre os grupos. Resultados: Vinte e dois pacientes foram recrutados em cada grupo. Um paciente perdeu o acompanhamento no grupo CuNiTi. Não foram observadas diferenças estatisticamente significativas entre os grupos quanto à eficiência do alinhamento (p>0,05). A comparação intergrupos revelou que as alterações na RRAE medida em três dimensões não foram estatisticamente significativas (p>0,05), exceto para o incisivo central inferior direito, que apresentou aumento da RRAE no grupo NiTi (p<0,01). Conclusão: Os dois tipos de fios de alinhamento apresentaram taxa de alinhamento semelhante em todos os momentos. A medida da reabsorção radicular não diferiu entre o grupo NiTi e CuNiTi, exceto para o incisivo central inferior direito, que apresentou maior reabsorção no grupo NiTi.

14.
Braz. oral res. (Online) ; 37: e065, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1439737

RESUMEN

Abstract The aim of this study was to quantify the force exerted by tandem archwires in a specific system of passive self-ligating bracket. Forty-eight thermo-activated nickel-titanium orthodontic archwires were separated into four groups (n = 12): G1 - two .014" + .014" round archwires; G2 - two .014" + .016" round archwires; G3 - .014" x .025" rectangular archwire; and. G4 - .016" x .022" rectangular archwire. Brackets were fixed onto teeth 1.5 to 2.5 using a device that represented the upper teeth, maintaining an interbracket distance of 6.0 mm. The deflection tests were performed using the structure representative of tooth 1.1 as support on the Instron testing machine at a speed of 2.0 mm/min. The archwires were evaluated at deflections of 0.5 mm, 1.0 mm, and 1.5 mm. The data were analyzed by a generalized linear model, considering values at different deflections as repeated measurements in the same experimental unit (α = 0.5%). At 0.5 mm, higher forces were observed in G2 and G3, which did not differ significantly (p > 0.05). The lowest force was observed in G4 (p < 0.05). At 1.0 mm and 1.5 mm, the highest force was observed in G3, followed by G4 and G2 (p < 0.05). The lowest force was observed in G1 (p < 0.05). In general, tandem archwires (same or different calibers) in a specific passive self-ligating bracket exerted lower force when compared with rectangular archwires.

15.
Ortho Sci., Orthod. sci. pract ; 16(62): 97-105, 2023. ilus, tab
Artículo en Portugués | BBO - Odontología | ID: biblio-1444831

RESUMEN

Resumo O propósito deste estudo foi comparar a magnitude de torque de fios retangulares de níquel titânio (NiTi) estéticos e convencionais submetidos aos testes de torção. Foram testados fios comerciais de NiTi pré-contornados estéticos e convencionais de 4 marcas comerciais (American Orthodontics, Eurodonto, Orthometric e TP Orthodontics) de secção transversal 0.016" x 0.022". Os testes foram realizados em máquina de torção com rotação de 0° a 90° e foi analisado o comportamento na desativação em 20° e no torque máximo a 90°. Aos 20° no descarregamento, os fios estéticos e convencionais da American Orthodontics tiveram maior expressão de torque, enquanto os fios da Eurodonto convencional e TP Orthodontics estético apresentaram menor torque. No torque máximo a 90°, os fios que tiveram maior expressão foram da TP Orthodontics convencional e American Orthodontics estético, e os fios de menor torque foram da Eurodonto convencional e Orthometric estético. Não foram encontradas diferenças estatisticamente significativas quando os fios estéticos foram comparados entre si. Ao comparar fios estéticos e convencionais de mesma marca comercial, a única que apresentou diferença estatisticamente significativa foi a Eurodonto. Concluiu-se que, quando comparados os torques dos fios estéticos e convencionais de mesma marca, não foram encontradas diferenças estatisticamente significativas, exceto o da marca Eurodonto, que apresentou menor torque para os fios convencionais. (AU)


Abstract The purpose of this study was to compare the torque magnitude of aesthetic and conventional nickel titanium (NiTi) rectangular wires subjected to torsion tests. Commercial esthetic and conventional pre-contoured NiTi wires from 4 brands (American Orthodontics, Eurodonto, Orthometric, and TP Orthodontics) with a cross-section of 0.016" x 0.022" were tested. The tests were carried out in a torsion machine with rotation from 0º to 90° and the behavior in deactivation at 20° and at a maximum torque at 90° was analyzed. At 20° in unloading, American Orthodontics esthetic and conventional wires had higher torque, while conventional Eurodonto and TP Orthodontics esthetic wires had lower torque. At maximum torque (90°), the wires that had the highest torque were conventional TP Orthodontics and aesthetic American Orthodontics, and the wires with the lowest torque were conventional Eurodonto and aesthetic Orthometric. No statistically significant differences were found when the aesthetic threads were compared to each other. When comparing aesthetic and conventional wires from the same brand, the only one that showed a statistically significant difference was Eurodonto. It was concluded that, when comparing the torques of the aesthetic and conventional wires of the same brand, no statistically significant differences were found, except for the Eurodonto brand, which presented lower torque for the conventional wires. (AU)


Asunto(s)
Alambres para Ortodoncia
16.
Ortho Sci., Orthod. sci. pract ; 16(61): 44-55, 2023. ilus, tab
Artículo en Portugués | BBO - Odontología | ID: biblio-1509244

RESUMEN

Resumo Proposição: avaliar in vitro a rugosidade superficial de fios ortodônticos antes e após a compressão com pinças ortodônticas. Material E Métodos: 30 fios 0,014" de níckel-titânio termoativados (Neosentalloy, GAC) e 30 fios 0,019 x 0,025" de aço foram usados nos experimentos. Avaliou-se a rugosidade superficial com rugosímetro (NewViewTM 7100, Zygo), antes e após a compressão com alicate Weingart do lado esquerdo e pinça Mathieu do lado direito (Dentaurum). Foram determinados os parâmetros de rugosidade Ra (µm), Rq (µm), PV (µm), Srmax Iso (nm). Testes estat´siticos Wilcoxon foram realizados para analisar a variação dos parâmetros da rugosidade com nível de confiança de 95% e p<0,05. Resultados: Os fios redondos de NiTi apresentaram diferenças significaticas dos parâmetros Ra e Rq antes e após a compressão com pinça Mathieu. O emprego do alicate Weingart não alterou a rugosidade dos fios redondos. Os fios retangulares apresentaram diferenças significativas em todos os parâmetros com uso das duas pinças. As médias das diferenças dos parâmetros entre o alicate Weingart e a pinça Mathieu nos fios redondos, não foram estatisticamente significativos. Os fios retangulares apresentaram maior rugosidade com o emprego do alicate Weingart, com diferenças significativas. Conclusão: O uso do alicate tipo Weingart e da pinça tipo Mathieu aumentam a rugosidade dos fios de NiTi e de aço (AU)


Abstract Proposition: the surface roughness of orthodontic wires was evaluated in vitro before and after gripping with two different orthodontic pliers. Material And Methods: Units were made of 30 round heat-activated Nickel Titanium alloy wires 0,014" (Neosentalloy, GAC), and another group with 30 rectangular steel wires 0,019 x 0,025". The surface roughness was evaluated with a rugosimeter (NewViewTM 7100, Zygo), before and after gripping with Weingart plier on the left side and Mathieu plier on the right side (Dentaurum), in addition to the average difference in roughness between groups of the same types of wires with parameters Ra (µm), Rq (µm), PV (µm), Srmax Iso (nm). The variation of parameters with different clamps was evaluated (Wilcoxon test); different alloys by the same clamp, 95% confidence level and p<0.05. Results: The round wires showed significant differences (Ra and Rq) before and after being gripped with Mathieu plier. The roughness was higher after being gripped. Weingart pliers and round wires obtained the same results, with greater roughness after being clamped. Rectangular wires showed significant differences in all parameters, with both clamps. The means of the differences in the parameters between the Weingart pliers and the Mathieu forceps on the round wires were not statistically significant. In the rectangular wire, the values between the tweezers showed greater roughness with the grip of the Weingart pliers, with significant differences.Conclusion: After securing the orthodontic wires, the Weingart pliers and the Mathieu tweezers increased the roughness parameters (AU)


Asunto(s)
Alambres para Ortodoncia , Instrumentos Quirúrgicos , Estadísticas no Paramétricas , Atrición Dental
17.
Heliyon ; 8(9): e10560, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36325428

RESUMEN

Introduction: The release of metallic ions from orthodontic brackets and wires typically depends on their quality (chemical composition) and the medium to which they are exposed, e.g., acidic, alkaline, substances with a high fluoride concentration, etc. This review examines corrosion and wear of orthodontic brackets, wires, and arches exposed to different media, including: beverages (juices), mouthwashes and artificial saliva among others, and the possible health effects resulting from the release of metallic ions under various conditions. Objective: This review aims to determine the exposure conditions that cause the most wear on orthodontic devices, as well as the possible health effects that can be caused by the release of metallic ions under various conditions. Sources: A search was carried out in the Scopus database, for articles related to oral media that can corrode brackets and wires. The initial research resulted in 8,127 documents, after applying inclusion and exclusion criteria, 76 articles remained. Conclusion: Stainless steel, which is commonly used in orthodontic devices, is the material that suffers the most wear. It was also found that acidic pH, alcohols, fluorides, and chlorides worsen orthodontic material corrosion. Further, nickel released from brackets and wires can cause allergic reactions and gingival overgrowth into patients.

18.
J Orthod Sci ; 11: 7, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35754415

RESUMEN

This systematic review was aimed to test the null hypothesis that coating of orthodontic wires with nanoparticles does not affect the frictional properties at bracket--wire interface. Electronic database searches were performed up to September 2020. In vitro studies were considered for reviewing process. Study selection, data extraction, risk of bias assessment was performed during reviewing process. Only qualitative analyses of included literature were done due to the presence of heterogeneity among the studies. Out of 1,068 retrieved records, nine studies satisfied the inclusion criteria and included in this review. Studies were assessed at low risk to high risk of bias according to certain parameters. Wide variety of nanoparticles were used for surface coating of orthodontic wires of variable sizes, shapes, and materials like stainless steel, NiTi, and TMA and placed into the slots of different types of orthodontic brackets to evaluate the alteration in frictional and other mechanical properties. Most of the studies clearly indicate that coating with nanoparticles decreases the friction between wire and bracket interface under specified in vitro conditions. Furthermore, among the nine included studies, only two considered evaluation of effect of coated brackets on frictional and other mechanical properties and results were heterogeneous. The null hypothesis is rejected and it is concluded that the wires coated with nanoparticles might offer a novel opportunity to substantially reduce frictional resistance at bracket--wire interface during tooth movement. Further studies are necessary to strengthen the evidence regarding effect of coated brackets on frictional properties.

19.
Materials (Basel) ; 15(6)2022 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-35329446

RESUMEN

The aim of this study was to explore whether changes in the salivary pH influence mechanical properties, surface roughness, and ion release from NiTi archwires with various surface coatings, and discuss the clinical significance of the findings. The uncoated, rhodium-coated, and nitrified NiTi wires were immersed into artificial saliva of different pH values (4.8, 5.1, 5.5, and 6.6). Released nickel and titanium ions were measured with inductively coupled plasma-optical emission spectroscopy at the end of 28 days. Atomic force microscopy was used to measure the arithmetic average surface roughness Ra, the root-mean-square roughness Rq, and the maximum height of the asperities RZ. The nanoindentation hardness (HIT) and Young's modulus (EIT) measurements were performed. The change in the pH of artificial saliva is inversely proportional to the release of titanium from both coated and uncoated wires, and the release of nickel from uncoated wires. The surface roughness parameters of both coated and uncoated wires are unaffected by the change in the pH of artificial saliva. The change in the pH of saliva has minor influence on the hardness and Young's modulus of elasticity of both coated and uncoated wires. The concentration of released metal ions measured was below the recommended upper limit for daily intake; nevertheless, hypersensitivity effects cannot be excluded, even at lower concentrations and at low pH.

20.
Int Orthod ; 20(2): 100633, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35339407

RESUMEN

OBJECTIVES: The aim of this study was to measure the frictional resistance of different types of ligatures used on conventional and self-ligating brackets. MATERIALS AND METHODS: Monoblock (conventional) and Portia (self-ligating) brackets were used and the archwire used was nickel-titanium. On conventional brackets the ligatures tested were the Elastomeric type and steel 0.30 tie-wire. The groups were divided according to the ligature types (n=8): (1) conventional elastomeric ligature; (2) relaxed conventional elastomeric ligature; (3) elastomeric ligature in shape-8; (4) double vertical elastomeric ligatures; (5) double-crossed elastomeric ligatures; (6) crossed ligature; (7) steel wire ligature; and (8) self-ligating ligature (self-ligating bracket). A segment of five brackets, each ligature types, was mounted. The archwire, between the bracket and the ligature, was connected on Instron® Universal test machine to simulate the frictional resistance. The maximum frictional resistance was obtained, and the mean values were submitted to the analysis of variance (ANOVA) and the Tukey's post-hoc test (α=0.05). RESULTS: The elastomeric ligature in shape-8 showed the highest value compared with other groups (P<0.05). Although the crossed elastomeric ligature presented the lowest mean value and it was not statistically different regarding relaxed conventional elastomeric ligature, steel wire ligature and self-ligating (P≥0.05). CONCLUSIONS: The frictional resistance was influenced by ligature types. Elastomeric Ligature in shape-8 showed the highest frictional force. Crossed Elastomeric Ligature had the lowest frictional force value.